Inverter/Charger Installation
975-0639-01-01 Rev A 1–25
This guide for use by qualified personnel only
T
Figure 1-12 Installing the DC Switchgear
mounting hole
copper bus bar
connector (+)
pre-cut
mounting hole
positive (+) DC
terminal (red)
copper bus bar
connector (–)
pre-cut
mounting hole
negative (–) DC
terminal (black)
copper bus bar
connector
flat washer
nut
DC terminal
(1) Unpack the DC
Switchgear from its box, if
not already.
(2) Prepare four #10 (M5)
machine screws. Use two
screws to secure the DC
Switchgear to the installation
brackets of the Conext SW
and two screws to secure
the connecting bracket. The
connecting bracket attaches
to the Conext SW and DC
Switchgear.
(3) Remove the nuts and
washers from the inverter/
charger’s DC terminals, if
present.
(4) Position the DC
Switchgear next to the
inverter/charger carefully
aligning the mounting holes
with the pre-cut mounting
holes on the installation
bracket and the copper bus
bar connectors with the
inverter/charger’s DC
terminals.
(5) Fasten the screws to the
mounting holes on the DC
Switchgear with the pre-cut
mounting holes on the
installation bracket of the
inverter/charger.
(6) Fasten the screws to the
connecting bracket to join
the DC Switchgear and the
Conext SW together.
(7) Fasten the nuts and
washers of the inverter/
charger’s DC terminal bolts
to secure the copper bus
bars.
connecting
bracket
(5)
(5)
(6)
(7)