Conext™ SW Inverter Charger
Conext SW 2524 120/240 (865-2524)
Conext SW 4024 120/240 (865-4024)
Installation Guide
www.schneider-electric.com
TM
This guide for use by qualified personnel only
ConextSW-NA-InstallationGuide.book Page i Thursday, December 20, 2012 2:05 PM
Zobrazit stránku 0
1 2 3 4 5 6 ... 75 76

Shrnutí obsahu

Strany 1 - Conext™ SW Inverter Charger

Conext™ SW Inverter Charger Conext SW 2524 120/240 (865-2524)Conext SW 4024 120/240 (865-4024)Installation Guide www.schneider-electric.comTMThis guid

Strany 2 - 800-967-6917

Safetyviii 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyRegulatoryThe Conext SW Inverter/Charger is certified to appropriate Nort

Strany 3 - Conext SW Inverter Charger

Safety975-0639-01-01 Rev A ixThis guide for use by qualified personnel onlyFCC Information to the UserThis equipment has been tested and found to comp

Strany 4 - Copyright and Contact

xConextSW-NA-InstallationGuide.book Page x Thursday, December 20, 2012 2:05 PM

Strany 5 - About This Guide

975-0639-01-01 Rev A xiThis guide for use by qualified personnel onlyImportant Safety InstructionsPrecautions When Working With Batteries - - - - - -

Strany 6 - Related Information

Contentsxii 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyMultiple Unit Configuration - - - - - - - - - - - - - - - - - - - - - -

Strany 7 - Important Safety Instructions

975-0639-01-01 Rev A xiiiThis guide for use by qualified personnel onlyFigure 1-1 Materials List- - - - - - - - - - - - - - - - - - - - - - - - - - -

Strany 8 - AND FIRE HAZARD

xivConextSW-NA-InstallationGuide.book Page xiv Thursday, December 20, 2012 2:05 PM

Strany 9 - Important:

975-0639-01-01 Rev A xvThis guide for use by qualified personnel onlyTable 1-1 AC Wire Size In and Out of the Inverter/Charger- - - - - - - - - - - -

Strany 10 - Regulatory

xviConextSW-NA-InstallationGuide.book Page xvi Thursday, December 20, 2012 2:05 PM

Strany 11 - FCC Information to the User

975-0639-01-01 Rev A 1–1This guide for use by qualified personnel only1 InstallationThe following topics will be covered in this chapter.• Materials L

Strany 12

ConextSW-NA-InstallationGuide.book Page ii Thursday, December 20, 2012 2:05 PMYOUR ^,E/Z>dZ/DISTRIBUTORSOLIGENT800-967-6917www.soligen

Strany 13 - Contents

Installation1–2 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyMaterials ListThe Conext SW ships with the following items:• One Con

Strany 14 - 3 Wiring Diagrams

Materials List975-0639-01-01 Rev A 1–3This guide for use by qualified personnel onlyConext SW Front and Side PanelsBefore you begin to operate the Con

Strany 15

Installation1–4 975-0639-01-01 Rev AThis guide for use by qualified personnel only5 AC line terminals. See “AC and DC Terminals, Network and Communica

Strany 16

Materials List975-0639-01-01 Rev A 1–5This guide for use by qualified personnel onlyConext SW AC/DC/Ports Side PanelFigure 1-4 AC and DC Terminals, Ne

Strany 17

Installation1–6 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyConext SW Supplied AccessoriesNOTE: If any of the supplied accessori

Strany 18

Materials List975-0639-01-01 Rev A 1–7This guide for use by qualified personnel onlyConext SW Required AccessoryNOTE: The DC Switchgear is required by

Strany 19 - 1 Installation

Installation1–8 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyInstallation InformationBefore You Begin the InstallationBefore begi

Strany 20 - Materials List

Xanbus Network System975-0639-01-01 Rev A 1–9This guide for use by qualified personnel onlyXanbus Network SystemXanbus SystemThe Xanbus system include

Strany 21

Installation1–10 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyXanbus-enabled Products and Other AccessoriesProduct/Accessory (Sho

Strany 22

Installation Planning975-0639-01-01 Rev A 1–11This guide for use by qualified personnel onlyInstallation PlanningPlanning PreparationsThis section pro

Strany 23

Conext SW Inverter ChargerConext SW 2524 120/240 (865-2524)Conext SW 4024 120/240 (865-4024)Installation Guide www.schneider-electric.comConextSW-NA-I

Strany 24

Installation1–12 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyAC, DC, and Network ComponentsThe illustration below shows the diff

Strany 25 - Conext SW Required Accessory

Installation Planning975-0639-01-01 Rev A 1–13This guide for use by qualified personnel onlyThe illustration below shows which components you may need

Strany 26 - Installation Information

Installation1–14 975-0639-01-01 Rev AThis guide for use by qualified personnel onlySize of AC Input Wiring Wire size must be coordinated with the over

Strany 27 - Xanbus Network System

Installation Planning975-0639-01-01 Rev A 1–15This guide for use by qualified personnel onlyDC Disconnects and Overcurrent DevicesThe DC circuit from

Strany 28

Installation1–16 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyUnpacking and Inspecting the Conext SW Inverter/ChargerTo unpack an

Strany 29 - Installation Planning

Installation Planning975-0639-01-01 Rev A 1–17This guide for use by qualified personnel onlyInstallation Tools and MaterialsToo lsYou will need the fo

Strany 30 - Inverter panel

Installation1–18 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyInverter/Charger InstallationOverviewThis section provides detailed

Strany 31

Inverter/Charger Installation975-0639-01-01 Rev A 1–19This guide for use by qualified personnel onlyStep 1: Choosing a Location for the Inverter/Charg

Strany 32

Installation1–20 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyFigure 1-10 Conext SW Mounting Instructions5 7/8 in.149.0 mm(1) Pl

Strany 33 - AND BURN HAZARD

Inverter/Charger Installation975-0639-01-01 Rev A 1–21This guide for use by qualified personnel onlyStep 3: Connecting the AC Input and AC Output Wire

Strany 34 - LOAD HAZARD

Copyright and ContactCopyright © 2012 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its af

Strany 35 - Materials

Installation1–22 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyFigure 1-11 Conext SW AC INPUT and OUTPUT ConnectionsL1L2NAC Cable

Strany 36 - Inverter/Charger Installation

Inverter/Charger Installation975-0639-01-01 Rev A 1–23This guide for use by qualified personnel onlyStep 4: Installing the DC Switchgear and Connectin

Strany 37

Installation1–24 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyInstalling the DC Switchgear next to Conext SW Inverter/ChargerWARN

Strany 38 - 149.0 mm

Inverter/Charger Installation975-0639-01-01 Rev A 1–25This guide for use by qualified personnel onlyTFigure 1-12 Installing the DC Switchgearmounting

Strany 39 - SHOCK AND FIRE HAZARD

Installation1–26 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyConnecting the DC Cables to the DC SwitchgearWARNINGFIRE HAZARD• Us

Strany 40 - AC Cable

Inverter/Charger Installation975-0639-01-01 Rev A 1–27This guide for use by qualified personnel onlyFigure 1-13 Conext SW DC ConnectionsBattery or Bat

Strany 41 - SHOCK HAZARD

Installation1–28 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyStep 5: Connecting the BTS and Xanbus-enabled ComponentsBattery Tem

Strany 42 - FIRE HAZARD

Inverter/Charger Installation975-0639-01-01 Rev A 1–29This guide for use by qualified personnel onlyFigure 1-14 Conext SW BTS and Xanbus ConnectionsBa

Strany 43

Installation1–30 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyStep 6: Performing Checks Prior to Initial Start-UpBefore testing y

Strany 44 - POLARITY DAMAGE

Inverter/Charger Installation975-0639-01-01 Rev A 1–31This guide for use by qualified personnel onlyTesting in Invert ModeTo test the Conext SW in inv

Strany 45

975-0639-01-01 Rev A iiiThis guide for use by qualified personnel onlyAbout This GuidePurposeThe purpose of this Installation Guide is to provide expl

Strany 46

Installation1–32 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyMultiple Unit ConfigurationThe Conext SW inverter/chargers support

Strany 47 - Xanbus Stacking REM BTS

Multiple Unit Configuration975-0639-01-01 Rev A 1–33This guide for use by qualified personnel onlyDC Connections for Multiple Unit ConfigurationIndivi

Strany 48

Installation1–34 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyNeutral Wiring for Inverters in Multiple Unit ConfigurationIn a mul

Strany 49 - Installation Complete

Multiple Unit Configuration975-0639-01-01 Rev A 1–35This guide for use by qualified personnel onlyConfiguring the System for Multiple Unit OperationVe

Strany 50 - Multiple Unit Configuration

Installation1–36 975-0639-01-01 Rev AThis guide for use by qualified personnel onlySearch Mode Operation in Multiple Unit ConfigurationWhen two invert

Strany 51 - A DC fuse for

Battery Information975-0639-01-01 Rev A 1–37This guide for use by qualified personnel onlyBattery InformationBattery Bank SizingBattery capacity Batte

Strany 52

Installation1–38 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyEstimating Battery RequirementsCalculating Battery SizeStep 1: Comp

Strany 53 - CSW4024 00: Multi

Battery Information975-0639-01-01 Rev A 1–39This guide for use by qualified personnel onlyTable 1-4 Battery Sizing ExampleThis example illustrates how

Strany 54 - Wiring Schematic

Installation1–40 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyRestrictions on Motor SizeAn appliance may require three to six tim

Strany 55 - Battery Information

Battery Information975-0639-01-01 Rev A 1–41This guide for use by qualified personnel onlyBattery Cabling and Hook-up ConfigurationsSeveral smaller ba

Strany 56 - Calculating Battery Size

About This Guideiv 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyConventions UsedThe following conventions are used in this guide.

Strany 57 - Battery Bank Sizing Worksheet

Installation1–42 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyBattery Series ConnectionWhen batteries are connected with the posi

Strany 58 - Restrictions on Motor Size

975-0639-01-01 Rev A 2–1This guide for use by qualified personnel only2 SpecificationsNOTE: Specifications are subject to change without prior notice.

Strany 59 - Battery Parallel Connection

Specifications2–2 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyInverter SpecificationsNOTE: All inverter specifications are at no

Strany 60 - Battery Series Connection

Charger Specifications975-0639-01-01 Rev A 2–3This guide for use by qualified personnel onlyCharger SpecificationsNOTE: All charging specifications ar

Strany 61

Specifications2–4 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyAC Transfer SpecificationsNOTE: All transfer specifications are at

Strany 62 - Inverter Specifications

Environmental Specifications975-0639-01-01 Rev A 2–5This guide for use by qualified personnel onlyEnvironmental SpecificationsRegulatorySW 2524 120/24

Strany 63 - Charger Specifications

2–6ConextSW-NA-InstallationGuide.book Page 6 Thursday, December 20, 2012 2:05 PM

Strany 64 - Physical Specifications

975-0639-01-01 Rev A 3–1This guide for use by qualified personnel only3 Wiring Diagrams“Wiring Diagrams” illustrate the most basic BOS configurations

Strany 65 - Full power at ambient

Wiring Diagrams3–2 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyConextSW-NA-InstallationGuide.book Page 2 Thursday, December 20

Strany 66

Single-Inverter System (Off-Grid/Power Backup)975-0639-01-01 3–3This guide for use by qualified personnel onlySingle-Inverter System (Off-Grid/Power B

Strany 67

975-0639-01-01 Rev A vThis guide for use by qualified personnel onlyImportant Safety InstructionsREAD AND SAVE THESE INSTRUCTIONS - DO NOT DISCARDNOTE

Strany 68 - 3–2 975-0639-01-01 Rev A

3–4 975-0639-01-01This guide for use by qualified personnel onlyFigure 3-2 Single-Inverter System (Off-Grid/Backup) WiringL1L2InverterAC Distribution

Strany 69

Single-Inverter System Renewable Energy (Solar)975-0639-01-01 3–5This guide for use by qualified personnel onlySingle-Inverter System Renewable Energy

Strany 70 - 3–4 975-0639-01-01

3–6 975-0639-01-01This guide for use by qualified personnel onlyFigure 3-4 Dual-Inverter System Renewable Energy (Solar) WiringL1L2InverterAC Distrib

Strany 71

Dual-Inverter System Renewable Energy (Solar)975-0639-01-01 3–7This guide for use by qualified personnel onlyDual-Inverter System Renewable Energy (So

Strany 72 - 3–6 975-0639-01-01

3–8 975-0639-01-01This guide for use by qualified personnel onlyFigure 3-6 Dual-Inverter System Renewable Energy (Solar) WiringL1L2InverterAC Distrib

Strany 73

ConextSW-NA-InstallationGuide.book Page 3 Thursday, December 20, 2012 2:05 PM

Strany 74 - 3–8 975-0639-01-01

975-0639-01-01Printed in USAPrinted in ChinaSchneider Electricwww.schneider-electric.com For other country details please contact your local Schneider

Strany 75

Safetyvi 975-0639-01-01 Rev AThis guide for use by qualified personnel onlyNOTES:1. Follow these instructions and those published by the battery manuf

Strany 76 - Schneider Electric

Safety975-0639-01-01 Rev A viiThis guide for use by qualified personnel onlyPrecautions When Working With BatteriesImportant:Battery work and maintena